Product Electric Parameters | ||||
Input specification | Input voltage | AC100V---240V | ||
Input frequency | 50-60Hz | |||
Input surge | 20A@120VAC 40A@230VAC | |||
Output specification | Output voltage can be adjusted | ±10% | ||
Start-up time | <1S(input230V Io=100%) | |||
keep time | >20mS (input230V,Io=100%) | |||
Voltage regulation | (Full load) <0.5% | |||
Protection function | Overload protection | 105% - 150% rated power, automatic recovery | ||
Over-voltage protection | 105% - 150% of the rated voltage | |||
Insulation intensity | Input---output | 1500VAC/1min | ||
Input---ground | 1500VAC/1min | |||
Input---ground | 500VAC/1min | |||
Safety standards | According with GB4943, UL60950-1,EN60950-1 standards. | |||
E M C standards | According with GB9254, EN55022 class A EN61347-2-13:2008 standards | |||
Environmental | working temperature | - 20 ° ~ 60 ° c / 20% ~ 90% RH (no frost) | ||
Storage temperature | - 40 ° ~ 85 ° c / 10% ~ 95% RH (no frost) | |||
height above sea level | <2000M | |||
Cooling method | Cooling method | Natural cooling air convection | ||
Product Type Table | ||||
Product model | output specification | ripple, noise | efficiency | |
AE-1207000 | 12V | 7A | 100mVp | >86% |
Description:
1. input voltage range of AC90-264V. wide voltage input, comply with the global standard.
2. input voltage frequency: 47-63Hz
3. output voltage: according to customer requirements
4. output voltage adjustable rate: 1%
5. rated output current can be customized
6. current output range 0-5A
Protections
1) over voltage protection: 120%min
2) over current protection: 120%min
3) over protection
4) Short-circuit protection: automatic recovery
5) Load regulation: ±5%
Environmental requirement
1)operating temperature: 0-40
2)storage temperature: -20-85
3)opera ting relative humidity:595%RH
4) Withstanding voltage: AC 3,000V (minimum), 5mA (maximum)
5Insulation resistance: DC 500V 100MΩ (minimum)
Advantages
1. AC input power suitable for the world
2. Soft-start current can reduce the AC input impact efficiency
3. With short-circuit and overload protection
4. Compact size ,light weight
5. 100%full-load burning test
6. Installed with EMI filter ,minimum wave
Applications:
100-240Vac 50-60Hz AC DC Adapter 12V 3.5A KC
can be applied in security equipments, portable equipments, telecommunication equipments, consumer equipments, and other equipments.
Security equipment: monitoring camera, hard disk video recorder, security system, control equipment, monitoring equipment, etc.
Portable equipment: portable DVD, radio, mobile hard disk box, portable tools, charger, lithium ion battery, game machine, language repeater, walkman, digital products, tablet PC, etc.
Telecommunication equipment: router, microprocessor system, ADSL equipment, telephone composite aircraft, hub, telecommunications terminal equipment, cell phone, etc.
Consumer equipment: LCD TV, HD player, DVD players, digital photo frame, electronic refrigerator, acoustics, LED lamps and lanterns, small power electric appliances, electric tools, audio-video products, mini TV, decorative lighting, massager, LED lighting, electric bicycle battery charger, small size LCD TV and set top box, air cleaner, LCD, computer monitor, etc.
Other equipment: industrial automation control, military equipment, scientific research equipment, industrial control equipment, electric power equipment, medical equipment, semiconductor refrigeration and heating, computer chassis, instrument power supply, printer, testing equipment, and almost any other portable type equipment.
Output | DC output voltage | 5V | 12V | 24V |
Output voltage tolerance | ±5% | ±5% | ±5% | |
Rated output current | 5A | 3A | 1.5A | |
Output current | 0~5A | 0~3A | 0~1.5A | |
Output power | 25W | 36W | 36W | |
Ripple and noise | mVp-p | 100mVp-p | 240mVp-p | |
Line regulation | ±1% | ±1% | ±1% | |
Load regulation | ±5% | ±5% | ±5% | |
Voltage adj. range | Fixed | |||
Setup rise hold up time | 500ms,20ms,50ms/230VAC 500ms,20ms,15ms/115VAC at full load | |||
Input | Input voltage range | 90~264VAC 135~370VDC | ||
AC input current | 0.7A/100VAC | |||
Efficiency | 75% | 80% | 83% | |
AC inrush current | 45A/230VAC | |||
Leakage current | 0.75mA/240VAC | |||
Frequency range | 47~63Hz | |||
Protection characteristic | Over load protection | 110%~150%rated output power | ||
Protection mode: Hiccup mode, auto-recovery after fault condition is removed. | ||||
Environment | Working temperature | 0℃~+50℃ | ||
Working humidity | 20%~90% RH non-considering | |||
Storage Temp,humidity | -20℃~+85℃,10~95%RH | |||
Temp.coefficient | ±0.03% /℃(0~50℃) | |||
Vibration | 10~500Hz, 2G 10min./1 cycle ,period for 60 min. each along X Y Z axes | |||
Safety | Withstand voltage | I/P-O/P:3000 VDC | ||
Safety standards | EN60950 | |||
Insulation resistance | I/P-O/P:100M Ohms/500VDC/25℃/70%RH | |||
EMI conduction&radiation | Compliance to EN55024, EN61000-3-3 | |||
EMS immunity | Compliance to EN61000-3-3 | |||
Harmonic current | Compliance to | |||
Others | Weight/Packing | 0.22kg/50PCS/12.5kg | ||
Dimension | 115*48*30MM | |||
Connector | Plug | 5.5X2.1mm 5.5X2.5mm | ||
Cable | 1.2m | |||
Remark: 1.All parameters are specified at 230VAC input, rated load, 27℃ 70%RH ambient 2. Ripple and noise are measured at 20MHz by using a 12 inch Twisted pair terminated with 0.1u and 47u capacitor 3. Tolerance: includes set up tolerance, line regulation, load regulation 4. DC voltage : the output voltage set at point measure by plug terminal &50% load 5.Line regulation is measured from low line to high line at rated load 6.Load regulation is measured from 20% to 100% rated load 7.The power supply is considered a component which will be installed into a final equipment .The final equipment must be re-confirmed that it stills meets EMC directives |